JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Reinhardt, D. J.
Right arrow Articles by Malecka-Griggs, B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Reinhardt, D. J.
Right arrow Articles by Malecka-Griggs, B.

 Previous Article  |  Next Article 

J Clin Microbiol. 1980 August; 12(2): 199-204

Selective Nonroutine Microbial Surveillance of In-Use Hospital Nebulizers by Aerosol Entrapment and Direct Sampling Analyses of Solutions in Reservoirs

Donald J. Reinhardt1, Christopher Kennedy2 and Blanche Malecka-Griggs1

1 Biology Department, Georgia State University, Atlanta, Georgia 30303
2 Respiratory Therapy Department, Georgia State University, Atlanta, Georgia 30303

ABSTRACT

Effluent aerosols and liquid reservoir samples from 255 in-use hospital nebulization devices were analyzed by Aero-Test samplers (Olympic Corp.) and direct dilution procedures (0.1-, 0.01-, and 0.001-ml plated samples). Thirty-five percent (89 of 255) of the in-use hospital reservoir samples were positive by direct dilution, and 24% (61 of 255) were positive by Aero- Test samplers. Acinetobacter calcoaceticus var. anitratus was found either alone or in association with Pseudomonas spp. in 50% of all the contaminated in-use reservoirs. This indicates a high endemicity for Acinetobacter in the environment studied. Viable microbes in the reservoirs of contaminated nebulizers ranged from as few as 20 to >2 x 105 colony-forming units/ml. Microbial contamination at moderate to heavy levels (1 x 104 to >2 x 105) was regularly detected by both procedures. Microbial densities of 103 colony-forming units/ml and less in contaminated reservoirs often were negative in the Aero- Test but positive by direct dilution techniques. These hospital-based results were similar to laboratory data obtained with sterile nebulizers intentionally contaminated in graduated densities with either Staphylococcus aureus or Pseudomonas aeruginosa. Sensitivity of the Aero- Test system was best when ≥104 colony-forming units/ml were present in the reservoirs of operating nebulizers. The manufacturer suggests that five or less colonies appearing after sampling on Aero- Test plates upon 48-h incubation does not indicate contamination of the reservoir. Our data show that even a single colony, particularly if it is typical, water-associated, gram-negative bacterial species, may well indicate low levels of reservoir contamination. Both the Aero- Test and direct dilution methods indicated the need for more rigorous management of the in-use respiratory therapy equipment in the hospital surveyed. These studies demonstrate the value of selective nonroutine surveillance for identifying potential or actual contamination problems of in-use nebulizing equipment, particularly when recommended care guidelines are not followed due to choice or unawareness. Ameliorative-corrective measures, which included routine 24-h substitution of old units with new sterile units, were initiated as a result of this surveillance program.


J Clin Microbiol. 1980 August; 12(2): 199-204







Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
Antimicrob. Agents Chemother. Clin. Microbiol. Rev.
Clin. Vaccine Immunol. ALL ASM JOURNALS

Copyright © 1980 by the American Society for Microbiology. All rights reserved.