Comparison of LightCycler PCR, Rapid Antigen Immunoassay, and Culture for Detection of Group A Streptococci from Throat Swabs
J. R. Uhl,1 S. C. Adamson,2 E. A. Vetter,1 C. D. Schleck,3 W. S. Harmsen,3 L. K. Iverson,4 P. J. Santrach,4 N. K. Henry,5 and F. R. Cockerill1,6*
Division of Clinical Microbiology,1
Department of Family Medicine,2
Department of Health Sciences Research,3
Division of Specimen Collection and Hospital/Clinic Laboratories,4
Division of Pediatric Infectious Diseases,5
Division of Adult Infectious Diseases, Mayo Clinic and Foundation, Rochester, Minnesota 559056
Received 13 June 2002/
Returned for modification 12 August 2002/
Accepted 17 October 2002
We compared the performance characteristics of a real-time PCR method, the LightCycler Strep-A assay (Roche Applied Science, Indianapolis, Ind.), to those of a rapid antigen immunoassay, the Directigen 1-2-3 Group A Strep Test kit (BD Diagnostic Systems, Sparks, Md.), and a standard culture method for detection of group A streptococci (GAS) from 384 throat swabs. The LightCycler PCR produced more positive results (n = 58) than either culture (n = 55) or the Directigen immunoassay (n = 31). The results of the LightCycler PCR and the Directigen method were independently compared to the results of the accepted "gold standard," bacterial culture. The sensitivities, specificities, and positive and negative predictive values for this comparison were as follows: for the Directigen method, 55, 99, 97, and 93%, respectively; for the LightCycler PCR, 93, 98, 88, and 99%, respectively. In no case was a throat swab positive by both the LightCycler PCR and the Directigen method but negative by culture. The medical histories of patients whose throat swabs were negative by culture but positive by either the LightCycler PCR (n = 7) or the Directigen method (n = 1) were reviewed. All of these patients had signs or symptoms compatible with GAS disease, and therefore, all of these discordant positive results (along with positive results by either the Directigen method or the LightCycler PCR that agreed with the culture results) were counted as true positives for statistical analysis. For this analysis, the LightCycler PCR detected more true-positive results than the culture method (58 versus 55 swabs); however, this difference was not statistically significant (P = 0.5465). In contrast, statistically significantly more true-positive results occurred by culture than by the Directigen method (55 versus 31 swabs; P < 0.0001) and by the LightCycler PCR than by the Directigen method (58 versus 31 swabs; P < 0.0001). The LightCycler PCR is a suitable stand-alone method for the detection of GAS from throat swabs. Additionally, this method requires less than half the personnel time and the procedure can be completed in considerably less time (
1 h) than our standard approach (up to 2 days) for detection of GAS in throat swabs (i.e., testing by the Directigen method with negative results verified by culture).
* Corresponding author. Mailing address: Division of Clinical Microbiology, Mayo Clinic, 200 First St., SW, Rochester, MN 55905. Phone: (507) 284-2901. Fax: (507) 284-4272. E-mail: Cockerill.Franklin{at}mayo.edu.
Journal of Clinical Microbiology, January 2003, p. 242-249, Vol. 41, No. 1
0095-1137/03/$08.00+0 DOI: 10.1128/JCM.41.1.242-249.2003
Copyright © 2003, American Society for Microbiology. All Rights Reserved.
This article has been cited by other articles:
-
Lee, J. H., Uhl, J. R., Cockerill, F. R. III, Weaver, A. L., Orvidas, L. J.
(2008). Real-Time PCR vs Standard Culture Detection of Group A {beta}-Hemolytic Streptococci at Various Anatomic Sites in Tonsillectomy Patients. Arch Otolaryngol Head Neck Surg
134: 1177-1181
[Abstract]
[Full Text]
-
Fox, J. W., Cohen, D. M., Marcon, M. J., Cotton, W. H., Bonsu, B. K.
(2006). Performance of Rapid Streptococcal Antigen Testing Varies by Personnel. J. Clin. Microbiol.
44: 3918-3922
[Abstract]
[Full Text]
-
Natarajan, G., Johnson, Y. R., Zhang, F., Chen, K. M., Worsham, M. J.
(2006). Real-Time Polymerase Chain Reaction for the Rapid Detection of Group B Streptococcal Colonization in Neonates. Pediatrics
118: 14-22
[Abstract]
[Full Text]
-
Morozumi, M., Nakayama, E., Iwata, S., Aoki, Y., Hasegawa, K., Kobayashi, R., Chiba, N., Tajima, T., Ubukata, K., the Acute Respiratory Diseases Study Group,
(2006). Simultaneous Detection of Pathogens in Clinical Samples from Patients with Community-Acquired Pneumonia by Real-Time PCR with Pathogen-Specific Molecular Beacon Probes. J. Clin. Microbiol.
44: 1440-1446
[Abstract]
[Full Text]
-
Espy, M. J., Uhl, J. R., Sloan, L. M., Buckwalter, S. P., Jones, M. F., Vetter, E. A., Yao, J. D. C., Wengenack, N. L., Rosenblatt, J. E., Cockerill, F. R. III, Smith, T. F.
(2006). Real-Time PCR in Clinical Microbiology: Applications for Routine Laboratory Testing. Clin. Microbiol. Rev.
19: 165-256
[Abstract]
[Full Text]
-
Davignon, L., Walter, E. A., Mueller, K. M., Barrozo, C. P., Stenger, D. A., Lin, B., on behalf of the Epidemic Outbreak Surveillance Co,
(2005). Use of Resequencing Oligonucleotide Microarrays for Identification of Streptococcus pyogenes and Associated Antibiotic Resistance Determinants. J. Clin. Microbiol.
43: 5690-5695
[Abstract]
[Full Text]
-
Issa, N. C., Espy, M. J., Uhl, J. R., Harmsen, W. S., Mandrekar, J. N., Gullerud, R. E., Davis, M. D., Smith, T. F.
(2005). Comparison of Specimen Processing and Nucleic Acid Extraction by the Swab Extraction Tube System versus the MagNA Pure LC System for Laboratory Diagnosis of Herpes Simplex Virus Infections by LightCycler PCR. J. Clin. Microbiol.
43: 1059-1063
[Abstract]
[Full Text]
-
Gerber, M. A., Shulman, S. T.
(2004). Rapid Diagnosis of Pharyngitis Caused by Group A Streptococci. Clin. Microbiol. Rev.
17: 571-580
[Abstract]
[Full Text]
-
Bourbeau, P. P., Heiter, B. J.
(2004). Use of Swabs without Transport Media for the Gen-Probe Group A Strep Direct Test. J. Clin. Microbiol.
42: 3207-3211
[Abstract]
[Full Text]
-
Bourbeau, P. P.
(2003). Role of the Microbiology Laboratory in Diagnosis and Management of Pharyngitis. J. Clin. Microbiol.
41: 3467-3472
[Full Text]
Copyright © 2003 by the American Society for Microbiology. All rights reserved.